SPECIFICATIONS:
Material: Hot Rolled Steel
Breaking Point: 50 Kg/Mm2
Shear Strength: 40 Kg/Mm2
Elastic Limit: 35 Kg/Mm2
Width: Min. 1000 Mm/Max. 2500 Mm
Thickness: Min. 8 Mm/Max. 20 Mm
Line:
Introduction Speed: 5 M/Minute
Working Speed: 15 To 20 M/Minute
Shear Cycle: Max. 20 Cuts/Min. @ Full Cycle
Length Tolerance: -0/+2 Mm
Coil:
Mandrel Dia. Entry: 610-850 Mm
Entry Max. Dia.: 2000 Mm
Entry Max. Weight: 30 Ton
I.D.: 610 Mm Min.
O.D.: 1,000 Mm Min./2,000 Mm Max.
Products:
Length: 1,000 Mm Max./10,000 Mm Max.
Height: 400 Mm Max. (Incl. Supports)
Weight: 3.5 Mt
Performance:
Hydraulic Flying Shear: Speed Thickness Number Of Cuts
5 M/Min. 15 Mm 20 Cuts/Minute
10 M/Min. 15 Mm 20 Cuts/Minute
20 M/Min. 12 Mm 15 Cuts/Minute
Electrics:
D.C. Motors: 440 V D.C.
A.C. Motors: 380v/50 Hz.
Electromagnetic Brakes: 380v/50 Hz.
Electro-Valves: 220v/50 Hz.
Control Circuits: 220v/50 Hz.
Feeding:
Tension: 380v +5%
Frequency: 50 Hz.
Power: 20 Ka
Absorbed Power: 400 Kw
Transformer Power: 630 Kva
Converter: Thyristor Type
The Line Is Composed Of:
1) Loading Ramp
2) Coil Car
3) Uncoiler - Cone Type
4) Peeler & Pinch Rolls
5) Flattener
6) Entry Edge Guides
7) #1 Conveyor
8) Edge Guides
9) Pinch Rolls
10) Edge Trimmer Double Stub, Each Head Independently Driven
11) Dual Scrap Chopper
12) Scrap Evacuation
13) #2 Conveyor
14) Edge Guides
15) Pinch Rolls
16) Precision Leveller
17) Pinch Rolls
18) Flying Shear
19) #1 Exit Conveyor
20) Stacker - End Discharge
21) #2 Exit Conveyor
Equipment Description:
1) Coil Loading Ramp:
Hydrauically Operated Wedges
2) Coil Car:
Positioning Through Proportional Control Valve.
3) Uncoiler:
Driven By (2) Motors 1 Kw Each With (2) Electro-Magnetic Clutches
And
(2) Pneumatic Disk Brakes.
Tension Control Through Pressure Regulator
Positioning Through Proportional Control Hydraulic Valve
Coil Holddown. Rolls Rotation Through A.C. Motor.
4) Peeler & Pinch Roll:
Operated Through 30 Kw Gear Motor.
Opening Of Rolls Through Proportional Control Hyd. Valve
Oscillating Lower Roll Through Proportional Control Hyd. Valve.
Longitudinal Coil Opening Table Driven Through
Proportional Control Hyd. Valve
Vertical Coil Opening Table Driven Through Proportional
Control Hyd. Valve.
Pressure Roll Positioning Through Proportional Control Hyd. Valve.
Pressure Roll Lowering Proportional Control Hydraulic Valve.
5) Flattener:
Driven By 250 Kw D.C. Motor With Forced Ventilation &
Control With Tachometric Dynamo.
5 Rolls (2 Over 3) With Pinch Rolls
Roll Diameter: 300 Mm
6) Entry Edge Guides:
Driven By 2,2 Kw Gear Motor With Electro-Magnetic Brake
7) #1 Conveyor:
8) Edge Guides
9) #2 Pinch Rolls:
Operated Through 30 Kw Gear Motor
Opening/Closure Rolls Through Proportional Control Hyd. Valve.
10) Edge Trimmer
Double Stub, Each Head Independently Driven
11) Dual Scrap Chopper
12) Scrap Evacuator:
With Hydraulic Valve & Electro-Magnetic Clutch Coupling
13) #2 Conveyor:
14) #2 Edge Guides:
Driven By 2.2 Kw Gear Motor With Electro-Magnetic Disk Brake.
15) Pinch Rolls:
16) Precision Leveller: 15 Rolls (7 Over 8)
Roll Diameter: 180 Mm
7 Series Of Backups
17) #3 Pinch Roll:
Driven By 10 Kw D.C. Motor With Speed Fitting's
Regulation Through Potentiometer +/- 10%.
18) Flying Shear:
Hydraulically Operated With Hydraulic Central A.C. Motor
75 Kw Car Driven Through Hydraulic Servo Valve
Mechanical Cutting: A.C. Motor 132 Kw Air Driven With
Brake Clutch Impulse Counter For Length To Be Cutted.
19) #1 Exit Conveyor:
Driven By 10 Kw D.C. Motor With Speed Fitting's
Regulation Through Potentiometer +/- 10%.
20) Stacker:
Side Positioning Through No. 2 Proportional Control Hyd.
Valves Transversal Alignment With 2.2 Kw Gear Motor.
Lowering (Disappearance) Of The Wedge With Pneumatic
Electro-Valve Pneumatic Side Alignment.
Photo Electric Cell For Automatic Descent Of The Parcel
21) #2 Exit Conveyor:
Driven By 10 Kw D.C. Motor With Speed Fitting's
Regulation Through Potentiometer +/- 10%.
Absorption Data:
A. Air
A.1. Consumption: 35 M 3/H.
A.2. Pressure: 6 Kgcm2
B. Service Water
B.1. Flow: Approx. 200 1/Min.
B.2. Pressure: 3 Kgcm2
B.3. Temp: 5 C
B.4. Entry Temperance: 20 C
C. Electric Power
C.1. Voltage: 380v
C.2. Frequency: 50 Hz.
Plant Layout:
From Left To Right Looking At The Line From The Operator's Side.
Area Required: Approx. 85 Meters X 15 Meters
Photos And Layout Drawings Available.
Line Was Completely Rebuilt In 2001
Machines Presently In Storage, Ready For Shipment.
PRICE....................: SEND A QUOTATION!!!
Met Pro Machinery, Inc.
Oakland, MI 48363
P:248 693-1400
F:248 693-1411